## Configurations over UART/Serial TTY
|
||||
## Serial Terminal Applications
|
||||
|
||||
In order to send commands, you will need an application capable of communicating over serial. Please download and install one of the following:
|
||||
|
||||
- Windows
|
||||
- [PuTTY](https://www.chiark.greenend.org.uk/~sgtatham/putty/latest.html)
|
||||
- [RealTerm](https://sourceforge.net/projects/realterm/)
|
||||
- [Termite](https://www.compuphase.com/software_termite.htm)
|
||||
- MacOS
|
||||
- Linux
|
||||
- minicom - `sudo apt install minicom` || `sudo yum install minicom`
|
||||
|
||||
## Updatng Pyr0-Piezo Circuit Parameters over Serial
|
||||
|
||||
The Pyr0-Piezo onboard microcontroller can be adjusted over UART/TTY/Serial.
|
||||
|
||||
To set the below parameters using serial input, use the following:
|
||||
|
||||
- To change trigger active duration: `TRG_D` [integer for milliseconds]
|
||||
- To change gain factor: `GAIN_F` [integer for gain state - see note*]
|
||||
- To change ADC hysteresis value: `HYST` [integer]
|
||||
- To change sensor input pullup vRef low threshold: `VFOL` [integer in millivolts]
|
||||
- To change comparator trigger high threshold: `VCOMP` [integer in millivolts]
|
||||
- To change the duration between ADC measurements: `LOOP_D` [integer in milliseconds]
|
||||
- To change trigger active duration: `TRG_D [integer for milliseconds]`
|
||||
- To change gain factor: `GAIN_F [integer for gain state - see note*]`
|
||||
- To change ADC hysteresis value: `HYST [integer]`
|
||||
- To change sensor input pullup vRef low threshold: `VFOL [integer in millivolts]`
|
||||
- To change comparator trigger high threshold: `VCOMP [integer in millivolts]`
|
||||
- To change the duration between ADC measurements: `LOOP_D [integer in milliseconds]`
|
||||
- To update the internal vRef constant value **(see notes below): `CONST [long value]`
|
||||
|
||||
You can also enable or disable DEBUG output with: `DEBUG` [0|1]
|
||||
You can also enable or disable DEBUG output with: `DEBUG [0|1]`
|
||||
|
||||
You can query the current configuration with: `CONFIG`
|
||||
You can query the current state (including ADC measurements) with: `STATE`
|
||||
|
||||
To reset all settings to defaults, use: `RESET`
|
||||
|
||||
|
||||
These commands should be wrapped in this format:
|
||||
1CMD INT1
|
||||
`CMD INT`
|
||||
|
||||
Examples:
|
||||
|
||||
|
|
@ -29,6 +43,7 @@ Examples:
|
|||
|
||||
*Note for Gain Factor:
|
||||
The gain STATE is representative of these values:
|
||||
|
||||
- 0 = 3x
|
||||
- 1 = 3.5x
|
||||
- 2 = 4.33x
|
||||
|
|
@ -48,16 +63,13 @@ with this if you don't know what you're doing!
|
|||
|
||||
The reading can be fine-tuned by using a multimeter, and this equation:
|
||||
|
||||
```
|
||||
scale_constant = internal1.1Ref * 1023 * 1000
|
||||
`scale_constant = internal1.1Ref * 1023 * 1000`
|
||||
|
||||
where
|
||||
|
||||
internal1.1Ref = 1.1 * Vcc1 (per voltmeter) / Vcc2 (per readVcc() function)
|
||||
```
|
||||
`internal1.1Ref = 1.1 * Vcc1 (per voltmeter) / Vcc2 (per readVcc() function)`
|
||||
|
||||
If the scale_constant calculated is different from the default 1125300,
|
||||
update the voltMeterConstant variable in pP_config.h with the correct value.
|
||||
If the scale_constant calculated is different from the default 1125300, update the voltMeterConstant variable in pP_config.h with the correct value or use the `CONST` command
|
||||
|
||||
## Configuration in firmware
|
||||
|
||||
|
|
|
|||