updated Pyr0-Piezo configuration instructions with new parameters #docs
This commit is contained in:
parent
c2c6e6e640
commit
f744b4539a
1 changed files with 3 additions and 10 deletions
|
|
@ -6,11 +6,12 @@
|
|||
- To change gain factor: `GAIN_F` [integer for gain state - see note*]
|
||||
- To change the output logic: `LOGIC [0|1]` (0 for active low, 1 for active high)
|
||||
- To enable piezo plugged detection: `PZDET [0|1]` (0 for disabled, 1 for enabled)
|
||||
- To set the sensor logic output voltage: `VCCSW [0|1]` (0 for 3.3v, 1 for 5v)
|
||||
- To change ADC hysteresis value: `HYST` [integer in millivolts]
|
||||
- To change sensor input pullup vRef low threshold: `VFOL` [integer in millivolts]
|
||||
- To change comparator trigger high threshold: `VCOMP` [integer in millivolts]
|
||||
- To change the duration between ADC measurements: `LOOP_D` [integer in milliseconds]
|
||||
- To update the internal vRef constant value **(see notes below): `CONST` [long value]
|
||||
- To calibrate internal vRef **(see notes below): `CONST` [Vcc measurement in millivolts]
|
||||
|
||||
You can also enable or disable DEBUG output with: `DEBUG [0|1]`
|
||||
|
||||
|
|
@ -51,15 +52,7 @@ The ADC reading function assumes an "ideal" multiplier constant. Each Atmega
|
|||
chip is slightly different, so it won't be completely accurate without tuning.
|
||||
Most of the time this won't be necessary, so don't mess with this if you don't
|
||||
know what you're doing!
|
||||
The reading can be fine-tuned by using a multimeter, and this equation:
|
||||
|
||||
`scale_constant = internal1.1Ref * 1023 * 1000`
|
||||
|
||||
where
|
||||
|
||||
`internal1.1Ref = 1.1 * Vcc1 (per voltmeter) / Vcc2 (per readVcc() function)`
|
||||
|
||||
If the scale_constant calculated is different from the default 1125300, update the voltMeterConstant variable in pP_config.h with the correct value or send a new value with `CONST`
|
||||
The reading can be fine-tuned by using a multimeter. Simply take a voltage readig at the Anode of D1 and input it's value in millivolts afte rthe `CONST` command
|
||||
|
||||