ESPHome firmware for Waveshare ESP32-S3 7" touch thermostat with direct HVAC relay control
Find a file
pyr0ball 3d47e80de6 fix: convert dial Fahrenheit input to Celsius before climate.control
The dual-arc setpoint dial uses a Fahrenheit-range scale (60-90) to
match the Lennox reference UI, but climate.control expects Celsius
throughout this codebase. Dragging the dial was sending raw
Fahrenheit values straight into target_temperature_low/high, which
would have commanded wildly wrong setpoints on live hardware.
Also fixes a stale comment pointing at the wrong file after the
panel.yaml extraction.
2026-07-12 00:57:28 -07:00
docs docs: disambiguate 'Phase 2' terminology now that LVGL work claimed that name 2026-07-11 23:00:04 -07:00
firmware fix: convert dial Fahrenheit input to Celsius before climate.control 2026-07-12 00:57:28 -07:00
.gitignore feat: scaffold ESPHome project for Waveshare ESP32-S3 7" thermostat 2026-07-11 19:53:54 -07:00
README.md feat: scaffold ESPHome project for Waveshare ESP32-S3 7" thermostat 2026-07-11 19:53:54 -07:00

Firecrest

ESPHome firmware for the Waveshare ESP32-S3-Touch-LCD-7B touch display board, configured as a smart thermostat panel with direct 24VAC HVAC control.

Requires Home Assistant with the ESPHome integration.

Hardware

See docs/build-guide-phase1-notes.md for full pin assignments and Phase 1 hardware decisions.

Flashing

  1. Copy firmware/secrets.example.yaml to firmware/secrets.yaml and fill in your values.
  2. esphome run firmware/waveshare-thermostat.yaml

License

MIT