formatting fix for markdown in pt100 page #docs
This commit is contained in:
parent
1ea927ecd9
commit
3b46a42023
1 changed files with 2 additions and 2 deletions
|
|
@ -1,4 +1,4 @@
|
|||
### PT100 RTD Thermal Sensor Integration
|
||||
# PT100 RTD Thermal Sensor Integration
|
||||
|
||||
The EasyPiezi (Rev 1.1.x and Rev 2.x.x) utilize an extra amp channel to allow the use of a PT100 RTD Thermal sensor with minimal additional components. The circuit is based on E3D's daughterboard designed for PT100 sensors.
|
||||
|
||||
|
|
@ -6,4 +6,4 @@ The EasyPiezi (Rev 1.1.x and Rev 2.x.x) utilize an extra amp channel to allow th
|
|||
|
||||
The circuit outputs a DC voltage that corresponds to the RTD's change in resistance, which in turn changes based on the temperature of the RTD. This output shares a common ground with other parts of the circuit, so only one additonal output pin is required to utilize it.
|
||||
|
||||
As this is a direct voltage reading, the usual TH# inputs on most controllers cannot be used (unless the user removes the pullup resistor attached to the input). Instead, the PT100 input must be attached to a bare analog input pin (any of the pins labeled A##, like A5 on Atmega controllers)
|
||||
As this is a direct voltage reading, the usual TH# inputs on most controllers cannot be used (unless the user removes the pullup resistor attached to the input). Instead, the PT100 input must be attached to a bare analog input pin (any of the pins labeled A##, like A5 on Atmega controllers)
|
||||
|
|
|
|||
Loading…
Reference in a new issue